Technical Information: Rainwater Goods

The Information in this literature is correct at the time of printing. However, specifications are subject to change without notice. Copperform roofing panels and associated products will perform as specified if fixed strictly in accordance with good trade and practice recommendations.

1.0 Technical Diagrams

2.0 Total Specifications

System Weight

Weight (Kg per m2)
Copper 4.9

3.0 Copper Specifications

Copperform rainwater goods are manufactured from sheet copper to AS 1566 standards or primary copper.

Physical Properties of Copper roofing panels

Norminal Gauge 0.55 mm
Panel Weight 4.9 kg/m2
Density 8940 kg/m3
Melting Point
1083 ºC
Composition 99.98% pure copper

Performance criteria of copper roofing panels

Fire / Flame Spread Copper is non-combustible. The very high thermal conductivity of copper allows a passage of heat away from the heat source
Heat As an excellent conductor of heat, copper heats up and cools down quickly.
UV Together with moisture, UV actually assists in the patination process. This increases the protective surface
Biological
The excellent biological control characteristics of copper will not support the growth of lichens, fungi or algae and this is now being widely recognized and being applied in sterile environments, such as hospitals.
Chemical Copper is resistant to most industrially generated airborne pollutants. In fact, sulphides, chlorides etc, in industrial smog actually accelerate the development of oxidization of the surface and the patina or protective coating. Copper is only attacked by strong oxidizing chemicals and acids such as hydrochloric, sulphuric or nitric acids. Fuel spills such as diesel, petrol, kerosene, etc will have no adverse effect on the performance of copper.

 

Compatibility

The Copperform roofing system has been designed to ensure the compatibility of all its components. Care should be taken that direct contact with or water run-off from copper does not adversely affect less noble materials such as steel, aluminum, zinc, etc.


Water run-off from bitumen and western red shingles will attack copper

Roof extras such as antennas, flue pipes, railings etc. could discolor copper roofing unless correctly flashed. Should there be any doubt as to the compatibility of materials with Copperform components, please contact the Copperform Advisory Service.


4.0 Warranty

Copperform offers a warranty on its products, subject to individual project evaluation.